10 17339 Rev L 08/04
EC SERIES INSTALLATION INSTRUCTIONS
WARNING!
Do not draw outside air from garage spaces. Exhaust products of gasoline engines are hazardous.
Do not install outside air ducts such that the air may be drawn from attic spaces, basements or above the
roofing where other heating appliances or fans and chimneys exhaust or utilize air. These precautions will
reduce the possibility of fireplace smoking or air flow reversal.
WARNING!
To prevent contact with sagging or loose insulation, the fireplace must not be installed against vapor barriers
or exposed insulation. Localized overheating could occur and a fire could result.
Figure 2 - Fireplace Locations
1. Fireplace Locations and Space Requirements
Several options are available to you when choosing a location for your fireplace. This fireplace may be used as a
room divider, installed along a wall, across a corner or used in an exterior chase. See Figure 2.
Locating the fireplace in a basement, near frequently opened doors, central heat outlets or returns, or other locations
of considerable air movement can affect the performance and cause intermittent smoke spillage from the front of the
fireplace. Consideration should be given to these factors before deciding on a location.
CLEARANCES!
A minimum 1/2 in. air
clearance must be
maintained at the back and
sides of the fireplace
assembly.
Chimney sections at any level
require a 2 in. minimum air
space clearance between the
framing and chimney section.
D. PRE-INSTALLATION PREPARATION
Figures 3 and 4 show two typical installations assuming an outside air kit is
being used. Therefore, an allowance must be made for 90-deg bends. Less
space is required when ducting goes directly outside without forming elbows.
Figure 3
Installation Along a Wall or an Exterior Chase
These are rough framing
dimensions only.
Figure 4 - Corner Installation
Cat. # A B
E/EC36 42 in. [1067mm] 45 in. [1143mm]
E/EC39 45 in. [1143mm] 48 in. [1219mm]
E/EC42 48 in. [1219mm] 51 in. [1295mm]
Cat. # A B C D E
E/EC36
42 in.
[1067mm]
72-3/4 in.
[1848mm]
36-3/8 in.
[924mm]
15-5/8 in.
[ 39 7mm]
51-3/8 in.
[1305mm]
E/EC39
45 in.
[1143mm]
75-3/4 in.
[1924mm]
37-3/8 in.
[962mm]
16-5/8 in.
[ 42 2mm]
53-1/2 in.
[1359mm]
E/EC42
48 in.
[1219mm]
78-3/4 in.
[2000mm]
39-3/8 in.
[1000mm]
17-5/8 in.
[ 44 8mm]
55-3/8 in.
[1407mm]
Vue de la page 9